AL to Copper Connector for Secure Aluminum-to-Copper PV Connections

AL to copper connector enables secure and low-loss connections between aluminum and copper conductors in solar power systems.

AL to Copper Connector
AL to Copper Connector

The AL to Copper Connector is designed to provide safe and stable electrical connections between aluminum and copper conductors in solar power systems. By minimizing contact resistance and reducing the risk of galvanic corrosion, it ensures efficient power transmission and long-term reliability. This connector is ideal for PV installations where aluminum cables need to interface seamlessly with copper components.

Features

A4-T adapter uses high quality weather resistance materials that guarantee long-term reliability and qualified by TUV. It could be installed on site. A4-T adapter could match 6mm2 to 16mm2Al alloy cables with 4 mm2 to 10mm2 copper cables, it could be wildly used in different applications. The lower contact resistance and higher current transfer capability ensure high product efficiency. A4-T adapter has IP68 water-proof rating and can be used in a wide operating temperature range from -40 °C to 85 °C.


Technical Data

Rated Voltage

IEC 1500V DC

Certified & Qualified

IEC 62852 TUV

Rated Current

50A

Ambient Temp

-40℃ up to +85℃

Contact Resistance

≤0.02mΩ

IP

IP68

Pollution Degree

Class II

Protection Degree

Class II

Fire Resistance

UL94-V0

Rated Impulse Voltage

16KV


Order Data

TYPE

Copper Cable Spec

Copper Cable OD

Al Cable Spec

Al Cable OD

A4-T-0406

4mm² /12 AWG

5.6mm~7.0mm

6mm² /10 AWG

5.6mm~7.0mm

A4-T-0610

6mm² /10 AWG

5.6mm~7.0mm

10mm² /8 AWG

6.8mm~8.5mm

A4-T-1016

10mm² /8 AWG

6.8mm~8.5mm

16mm² /6 AWG

8.0mm~10mm

Designed for mixed-metal conductor connections

Aluminum to Copper

Designed for mixed-metal conductor connections

Aluminum to Copper

Designed for mixed-metal conductor connections

Aluminum to Copper

Stable and efficient power transmission

Low Contact Resistance

Stable and efficient power transmission

Low Contact Resistance

Stable and efficient power transmission

Low Contact Resistance

FAQs

Q1: What is an AL to Copper connector used for?
It connects aluminum conductors to copper conductors in PV systems.

Q2: Why is a dedicated connector needed for mixed metals?
It helps improve connection stability and reduce resistance.

Q3: Where is this connector commonly used?
It is used where aluminum cables interface with copper components.

Q4: Does it support long-term reliability?
Yes, it is designed for stable long-term performance.

Q5: Is it suitable for solar power applications?
It is commonly used in PV installations.